Technical Specification
Parameters
25 Reportable parameters:
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD,
RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%,
LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#,
EOS#, BAS#
1 3D Scattergram
3 Histograms(WBC/BASO, RBC, PLT)
4 Research parameter:
ALY%, ALY#, LIC%, LIC#
Test Mode
● CBC mode, CBC+DIFF mode
● Venous whole blood,Capillary whole blood and Prediluted
Throughput
60 tests/hour
Performance
Parameter | Linearity Range | Carry Over | CV |
WBC | 0-300×109 /L | ≤0.5% | ≤2.0% |
RBC | 0-8×1012 /L | ≤0.5% | ≤1.5% |
HGB | 0-250g/L | ≤0.5% | ≤1.5% |
PLT | 0-3000×109 /L | ≤1.0% | ≤4.0% |
Sample Volume
CBC+DIFF mode: ≤20ul
CBC mode: ≤10ul
Data Memory
Up to 100,000 results(including histogram, scarttergram, patient information)
Display
14 inch touch screen, resolution 1366*768
Interface
1 LAN port, 4 USB ports
Communication
Support HL7 protocal/LIS
Internal RFID reader
Printout
Support various external USB printers, printout formats user definable
Size/Weight
L * W * H = 480*375*517(mm)
Weight: 36kg
Power Requirement
a.c.100-240V,50/60Hz
Working Environment
● Temperature:10-30℃
● Humidity: 20% – 85%
● Air pressure: 70~106kPa
● Working latitude: ≤3500m
Principle
Tri-angle laser scatter + flow Cytometry + impedance method for WBC.
● The 5 part differentiation of the white blood cell can be precisely done by collecting the optical signal when WBC pass through the laser beam.
● The front small-angle optical signal can reflect the information of the cell size.
● The front large-angle optical signal can reflect the information of nucleus’ structure and complexity.
● The side angle optical signal can reflect the information of granularity complexity.
3D Scattergram
3D holographic scattergram displays the accurate 5 part differentiation of WBC.
Dual methods for BASO measurement
The first innovative analyzer combined the optical method of BASO(BASO-O) and impedance method of BASO(BASO-I) together, it brings more reliable and stable measurement of BASO pathologic samples ,and minimized the analysis failure.
Premium large touch screen
14 inch touch screen with high resolution and sensitivity, can be operated by wearing gloves.
SMART-FLOW fluidic patent technology
The creative SMART-FLOW fluidic technology is a simple and efficient system, which makes AC 610 with good reliability and free of maintenance.
Accurate measurement for low value PLT
Advanced Sweep-Flow technology guarantees low PLT samples counted precisely.
Low volume sample consumption
CBC+DIFF mode:≤20ul, CBC mode: ≤10ul, Ideal choice for pediatrics and geriatri
Low running cost
Only three reagents needed for the test , low reagent consumption for single test.
Easy to use
ONE touch to start the test, ONE click to remove error, ONE screen for most of the daily operation.
Intelligent turn off power switch.
Product detail pictures:
Related Product Guide:
High-quality comes 1st; support is foremost; business is cooperation" is our small business philosophy which is regularly observed and pursued by our organization for OEM/ODM Supplier 1250µl Pipette Filter Tip - Auto 5-part hematology analyzer – LuoRon , The product will supply to all over the world, such as: Sri Lanka, Jakarta, Detroit, Since the establishment of our company, we've realized the importance of providing good quality goods and the best before-sales and after-sales services. Most problems between global suppliers and clients are due to poor communication. Culturally, suppliers can be reluctant to question points they do not understand. We break down these barriers to ensure you get what you want to the level you expect, when you want it.
By Queena from Naples - 2017.01.28 19:59
It's really lucky to find such a professional and responsible manufacturer, the product quality is good and delivery is timely, very nice.
By Janice from Greece - 2018.12.05 13:53