OEM Supply 50µl Filter - Special purpose centrifuge (2) - LuoRon
OEM Supply 50µl Filter - Special purpose centrifuge (2) – LuoRon Detail:
TD-450 PRP/PPP centrifuge
Specifically for beauty hospital, suitable for autologous fat transplantation surgery and autologous blood to extract for PRP cosmetic surgery.
Technique Parameter
Max Speed |
4500 r/min |
Max RCF |
3380 xg |
Max Capacity |
6x50ml syringe |
Speed Accuracy |
±10 r/min |
Motor |
Variable frequency drive motor |
Timer Range |
1min~99min59s/inching |
Noise |
≤60dB(A) |
Power Supply |
AC 220V 50HZ 10A |
Dimension |
550×450×365(L× W × H)mm |
Weight |
40 kg |
Rotor Technical Data
Rotor |
Capacity |
Max speed |
Max RCF |
NO.1 swing-out rotor |
16x10ml syringe |
4000rpm |
3000xg |
NO.2 swing-out rotor |
8x20ml syringe |
4000rpm |
2890xg |
NO.3 swing-out rotor |
4x50ml PRP kits/syringe |
4000rpm |
3380xg |
NO.4 swing-out rotor |
24x10ml vacuum blood collection tube |
4000rpm |
2890xg |
NO.5 angle rotor |
6x50ml syringe |
4500rpm |
3020xg |
TD-550 Special auto-balancing centrifuge for blood bank
Features & Advantages
● Microcomputer control, digital display ,brushless drive motor
● It can store 9 users programs.
● The shortest time of acceleration time ≤10S
● Electronic lid lock, stainless steel chamber
● RCF can be set up directly
● The operating parameters can be modified during operation
● Automatic fault diagnosis
● Designed for blood cross matching by polybrene test
● The speed can accelerate and decelerate fast and stop steadily
● Be used for blood cross matching, blood grouping and screening of irregular antibodies
Technique Parameter
Max Speed |
5500 r/min |
Max RCF |
4300 xg |
Max Capacity |
12x15ml |
Speed Accuracy |
±30r/min |
Timer Range |
1s~99min59s/inching |
The shortest time of acceleration |
≤10S |
Noise |
≤60dB(A) |
Power Supply |
AC 220V 50HZ 5A |
Dimension |
480x390x320(LxWxH)mm |
Weight |
25 kg |
Power |
500 W |
TD-RZ /DD-RZ milk fat testing centrifuge
The milk fat testing centrifuge is a special instrument for analyzing dairy products.. It is suitable for the measurement and analysis of milk fat in dairy products after centrifugation by pasteurization and Gerber method.
TD-RZ Features & Advantages
● Microcomputer control, digital display.
● Variable frequency drive motor, maintenance free.
● RCF can be set up directly.
● Stainless steel chamber.
● Automatic fault diagnosis, and can be programmed and operated.
TD-RZ Technique Parameter
Max Speed |
3300r/min |
Max RCF |
1920xg |
Max Capacity |
4x50ml Swing-out rotor (Pasteurized tube ) |
Speed Accuracy |
±10r/min |
Timer Range |
0~99min/inching |
Noise |
≤60dB(A) |
Power Supply |
AC 220V 50HZ 10A |
Dimension |
550x450x365(LxWxH)mm |
Weight |
40kg |
Power |
500 W |
4x50ml Swing-out rotor (Pasteurized tube )
Rotor |
Capacity |
Max speed |
Max RCF |
NO.1 swing-out rotor |
16x10ml syringe |
4000rpm |
3000xg |
NO.2 swing-out rotor |
8x20ml syringe |
4000rpm |
2890xg |
NO.3 swing-out rotor |
4x50ml PRP kits/syringe |
4000rpm |
3380xg |
NO.4 swing-out rotor |
24x10ml vacuum blood collection tube |
4000rpm |
2890xg |
NO.5 angle rotor |
6x50ml syringe |
4500rpm |
3020xg |
DD-RZ Features & Advantages
● Microcomputer control, LCD & Digital display
● Variable frequency drive motor, maintenance free
● RCF can be set up directly
● Stainless steel chamber.
● Automatic fault diagnosis, and can be programmed and operated.
● Import famous variable frequency controller, control speed accurately and be durable
● hot-typed model is optional.
It is a special instrument for dairy analysis.and suitable for centrifugation of fat in dairy products by pasteurization and geber method.
DD-RZ Technique Parameter
Max Speed |
1400r/min |
Max RCF |
350xg |
Max Capacity |
8x30ml Fixed-angle Rotor (Gerber tube) |
Speed Accuracy |
±10r/min |
Timer Range |
0~99H59min/inching |
Noise |
≤60dB(A) |
Power Supply |
AC 220V 50HZ 10A |
Dimension |
650x650x800(L x W x H)mm |
Weight |
90kg |
Power |
1.1 KW |
8x30ml Fixed-angle Rotor (Gerber tube)
TG-12 Hematocrit Centrifuge
Features & Advantages
● Microcomputer control, digital display
● Variable frequency drive motor, maintenance free
● 9 levels of acceleration and deceleration
● Independent Motor control, electronic safety lid lock
● RCF can be set up directly
● It is used for determination of volume fractions of erythrocytes in blood and also for separation of micro blood and solutions.
Technique Parameter
Max Speed |
12000r/min |
Max RCF |
15730xg |
Rotor Capacity |
24 or 12 Capillary tubes |
Speed Accuracy |
±10r/min |
Timer Range |
0~99min/inching |
Motor |
Variable frequency drive motor |
Noise |
≤60dB(A) |
Power Supply |
AC 220V/50HZ 5A |
Dimensions |
430x340x330mm(LxWxH)mm |
Weight |
28kg |
Power |
400 W |
Product detail pictures:
Related Product Guide:
We always get the job done being a tangible workforce making sure that we can easily give you the very best quality as well as finest selling price for OEM Supply 50µl Filter - Special purpose centrifuge (2) – LuoRon , The product will supply to all over the world, such as: United Arab Emirates, Jeddah, UAE, Our products are widely sold to Europe, USA, Russia, UK, France, Australia, Middle East, South America, Africa, and Southeast Asia, etc. Our solutions are highly recognized by our customers from all around the world. And our company is committed to continually improving effectiveness of our management system to maximize customer satisfaction. We sincerely hope to make progress with our customers and create a win-win future together. Welcome to join us for business!
By Bruno Cabrera from Iraq - 2018.09.21 11:44
Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
By Pamela from Macedonia - 2017.06.25 12:48