Factory supplied Pipette Yellow Tip - Blood collection tube automatic decapping centrifuge - LuoRon
Factory supplied Pipette Yellow Tip - Blood collection tube automatic decapping centrifuge – LuoRon Detail:
DD-5G Bio-safety filtering automatic decapping centrifuge
Features & Advantages
• RCF can be set up directly
• Three-layer steel body for safety
• Adopts Import famous variable frequency controller, control speed accurately and be durable
• Centrifugation and cap-off can be completed at once to avoid remixing of samples after separation
• Suitable for vacuum Vacuum blood collection tubes with various capacity
• UV sterilization device is optional
Technique Parameter
Max speed |
5000 r/min |
Max RCF |
5200 xg |
Max Capacity |
4x250ml |
Speed Accuracy |
±10r/min |
Timer Range |
1min~99H59min/inching |
Noise |
≤60dB(A) |
Power |
AC 220V 50HZ 15A |
Motor |
Variable frequency drive motor |
Dimension |
650x550x840(LxWxH) mm |
Weight |
135 kg |
Rotor Technical Data
Rotor |
Capacity |
Max Speed |
Max RCF |
NO. 1 Swing-out Rotor |
4×250 ml |
5000rpm |
5200xg |
NO. 2 Swing-out Rotor(with automatic cap off function) |
80x7ml |
4000rpm |
3400xg |
NO. 3 Swing-out Rotor (with automatic cap off function) |
120x7ml |
4000rpm |
3580xg |
NO. 4 Swing-out Rotor (with automatic cap off function) |
140x7ml |
4000rpm |
3580xg |
LD-5G Blood collection tube automatic decapping centrifuge
Features & Advantages
• Variable frequency drive motor,maintenance-free, control speed accurately
• Automatically remove the vacuum blood tube cap during centrifuging, improving work efficiency
• Instead of handmade cap-off, prevent reagent contact with the human body, reduce the risk of infection
• LCD & Digital display, touching key.
• Stainless steel chamber, all-steel body
• electronic locks
• Imported compressor, CFC-free refrigerants
• 40 levels of acceleration and deceleration,and it can store 12 users programs.
• RCF can be set up directly
• Three-layer steel body for safety
• Adopts Import famous variable frequency controller, control speed accurately and be durable
• Centrifugation and cap-off can be completed at once to avoid remixing of samples after separation
• Suitable for vacuum Vacuum blood collection tubes with various capacity
Technique Parameter
Max speed |
5000 r/min |
Max RCF |
5200 xg |
Max Capacity |
4x250ml |
Speed Accuracy |
±10r/min |
Temperature Range |
-20℃~40℃ |
Temperature Accuracy |
±1℃ |
Timer Range |
1min~99H59min/inching |
Noise |
≤60dB(A) |
Power Supply |
AC 220V 50HZ 15A |
Motor |
Variable frequency drive motor |
Dimension |
650x550x840(LxWxH) mm |
Weight |
165 kg |
Power |
1.8KW |
Rotor Technical Data
Rotor |
Capacity |
Max Speed |
Max RCF |
NO. 1 Swing-out Rotor |
4×250 ml |
5000rpm |
5200xg |
NO. 2 Swing-out (with automatic cap off function) |
80x7ml |
4000rpm |
3400xg |
NO. 3 Swing-out Rotor (with automatic cap off function) |
120x7ml |
4000rpm |
3580xg |
NO. 4 Swing-out Rotor (with automatic cap off function) |
140x7ml |
4000rpm |
3580xg |
TD-5G Benchtop Blood Tube Automatic Decapping Centrifuge
Features & Advantages
• Variable frequency drive motor,maintenance-free,control speed accurately.
• Automatically remove the vacuum blood tube cap during centrifuging, improving work efficiency
• Instead of handmade cap-off, prevent reagent contact with the human body, reduce the risk of infection.
• LCD & Digital display, touching key.
• Stainless steel chamber, all-steel body
• electronic locks.
• RCF can be set up directly.
• Centrifugation and cap-off can be completed at once to avoid remixing of samples after separation
• Suitable for vacuum Vacuum blood collection tubes with various capacity.
Technique Parameter
Max speed |
5000 r/min |
Max RCF |
5200 xg |
Max Capacity |
4x250ml |
Speed Accuracy |
±10r/min |
Timer Range |
1min~9999 min59s/inching/continuous |
Noise |
≤60dB(A) |
Power |
AC 220V 50HZ 10A |
Motor |
550x450x365(LxWxH) mm |
Dimension |
45 kg |
Rotor Technical Data
Rotor |
Capacity |
Max Speed |
Max RCF |
NO. 1 Swing-out Rotor |
4×250 ml |
5000rpm |
5200xg |
NO. 2 Swing-out Rotor |
32×7 ml |
4000rpm |
3100xg |
NO. 3 Swing-out Rotor (with automatic cap off function) |
56x7ml |
4000rpm |
3400xg |
NO. 4 Swing-out Rotor (with automatic cap off function) |
80x7ml |
Product detail pictures:
Related Product Guide:
Our pursuit and company goal is to "Always satisfy our customer requirements". We continue to develop and design superior quality products for both our old and new customers and achieve a win-win prospect for our clients as well as us for Factory supplied Pipette Yellow Tip - Blood collection tube automatic decapping centrifuge – LuoRon , The product will supply to all over the world, such as: Liverpool, Seattle, Mongolia, We set "be a creditable practitioner to achieve the continuous development and innovation" as our motto. We would like to share our experience with friends at home and abroad, as a way to create a bigger cake with our joint efforts. We have several experienced R & D persons and we welcome OEM orders.
By Mark from Guatemala - 2018.06.03 10:17
Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!
By Afra from Paraguay - 2018.09.23 17:37