Factory making Pipette Tip For Dragonlab - Special purpose centrifuge (2) - LuoRon
Factory making Pipette Tip For Dragonlab - Special purpose centrifuge (2) – LuoRon Detail:
TD-450 PRP/PPP centrifuge
Specifically for beauty hospital, suitable for autologous fat transplantation surgery and autologous blood to extract for PRP cosmetic surgery.
Technique Parameter
Max Speed |
4500 r/min |
Max RCF |
3380 xg |
Max Capacity |
6x50ml syringe |
Speed Accuracy |
±10 r/min |
Motor |
Variable frequency drive motor |
Timer Range |
1min~99min59s/inching |
Noise |
≤60dB(A) |
Power Supply |
AC 220V 50HZ 10A |
Dimension |
550×450×365(L× W × H)mm |
Weight |
40 kg |
Rotor Technical Data
Rotor |
Capacity |
Max speed |
Max RCF |
NO.1 swing-out rotor |
16x10ml syringe |
4000rpm |
3000xg |
NO.2 swing-out rotor |
8x20ml syringe |
4000rpm |
2890xg |
NO.3 swing-out rotor |
4x50ml PRP kits/syringe |
4000rpm |
3380xg |
NO.4 swing-out rotor |
24x10ml vacuum blood collection tube |
4000rpm |
2890xg |
NO.5 angle rotor |
6x50ml syringe |
4500rpm |
3020xg |
TD-550 Special auto-balancing centrifuge for blood bank
Features & Advantages
● Microcomputer control, digital display ,brushless drive motor
● It can store 9 users programs.
● The shortest time of acceleration time ≤10S
● Electronic lid lock, stainless steel chamber
● RCF can be set up directly
● The operating parameters can be modified during operation
● Automatic fault diagnosis
● Designed for blood cross matching by polybrene test
● The speed can accelerate and decelerate fast and stop steadily
● Be used for blood cross matching, blood grouping and screening of irregular antibodies
Technique Parameter
Max Speed |
5500 r/min |
Max RCF |
4300 xg |
Max Capacity |
12x15ml |
Speed Accuracy |
±30r/min |
Timer Range |
1s~99min59s/inching |
The shortest time of acceleration |
≤10S |
Noise |
≤60dB(A) |
Power Supply |
AC 220V 50HZ 5A |
Dimension |
480x390x320(LxWxH)mm |
Weight |
25 kg |
Power |
500 W |
TD-RZ /DD-RZ milk fat testing centrifuge
The milk fat testing centrifuge is a special instrument for analyzing dairy products.. It is suitable for the measurement and analysis of milk fat in dairy products after centrifugation by pasteurization and Gerber method.
TD-RZ Features & Advantages
● Microcomputer control, digital display.
● Variable frequency drive motor, maintenance free.
● RCF can be set up directly.
● Stainless steel chamber.
● Automatic fault diagnosis, and can be programmed and operated.
TD-RZ Technique Parameter
Max Speed |
3300r/min |
Max RCF |
1920xg |
Max Capacity |
4x50ml Swing-out rotor (Pasteurized tube ) |
Speed Accuracy |
±10r/min |
Timer Range |
0~99min/inching |
Noise |
≤60dB(A) |
Power Supply |
AC 220V 50HZ 10A |
Dimension |
550x450x365(LxWxH)mm |
Weight |
40kg |
Power |
500 W |
4x50ml Swing-out rotor (Pasteurized tube )
Rotor |
Capacity |
Max speed |
Max RCF |
NO.1 swing-out rotor |
16x10ml syringe |
4000rpm |
3000xg |
NO.2 swing-out rotor |
8x20ml syringe |
4000rpm |
2890xg |
NO.3 swing-out rotor |
4x50ml PRP kits/syringe |
4000rpm |
3380xg |
NO.4 swing-out rotor |
24x10ml vacuum blood collection tube |
4000rpm |
2890xg |
NO.5 angle rotor |
6x50ml syringe |
4500rpm |
3020xg |
DD-RZ Features & Advantages
● Microcomputer control, LCD & Digital display
● Variable frequency drive motor, maintenance free
● RCF can be set up directly
● Stainless steel chamber.
● Automatic fault diagnosis, and can be programmed and operated.
● Import famous variable frequency controller, control speed accurately and be durable
● hot-typed model is optional.
It is a special instrument for dairy analysis.and suitable for centrifugation of fat in dairy products by pasteurization and geber method.
DD-RZ Technique Parameter
Max Speed |
1400r/min |
Max RCF |
350xg |
Max Capacity |
8x30ml Fixed-angle Rotor (Gerber tube) |
Speed Accuracy |
±10r/min |
Timer Range |
0~99H59min/inching |
Noise |
≤60dB(A) |
Power Supply |
AC 220V 50HZ 10A |
Dimension |
650x650x800(L x W x H)mm |
Weight |
90kg |
Power |
1.1 KW |
8x30ml Fixed-angle Rotor (Gerber tube)
TG-12 Hematocrit Centrifuge
Features & Advantages
● Microcomputer control, digital display
● Variable frequency drive motor, maintenance free
● 9 levels of acceleration and deceleration
● Independent Motor control, electronic safety lid lock
● RCF can be set up directly
● It is used for determination of volume fractions of erythrocytes in blood and also for separation of micro blood and solutions.
Technique Parameter
Max Speed |
12000r/min |
Max RCF |
15730xg |
Rotor Capacity |
24 or 12 Capillary tubes |
Speed Accuracy |
±10r/min |
Timer Range |
0~99min/inching |
Motor |
Variable frequency drive motor |
Noise |
≤60dB(A) |
Power Supply |
AC 220V/50HZ 5A |
Dimensions |
430x340x330mm(LxWxH)mm |
Weight |
28kg |
Power |
400 W |
Product detail pictures:
Related Product Guide:
We are going to dedicate ourselves to providing our esteemed buyers together with the most enthusiastically thoughtful products and services for Factory making Pipette Tip For Dragonlab - Special purpose centrifuge (2) – LuoRon , The product will supply to all over the world, such as: Ukraine, Pakistan, Kuala Lumpur, In the increasingly competitive market, With sincere service high quality products and well-deserved reputation, we always offer customers support on products and techniques to achieve long-term cooperation. Living by quality, development by credit is our eternal pursuit, We firmly believe that after your visit we will become long-term partners.
By Andrew from Johannesburg - 2017.12.02 14:11
The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
By Rosalind from Ghana - 2018.06.26 19:27