LD-5M Floor Standing Low Speed Refrigerated Centrifuge
Technique Parameter
Max Speed |
5000 r/min |
Max RCF |
5200xg |
Max Capacity |
4x800ml(4000rpm) |
Speed Accuracy |
±10r/min |
Temp Accuracy |
±1℃ |
Temp Range |
-20℃~40℃ |
Timer Range |
1min~99H59min/inching |
Noise |
≤60dB(A) |
Power Supply |
AC 220V 50HZ 15A |
Dimension |
650x550x840(LxWxH)mm |
Weight |
150 kg |
Power |
1.8 KW |
Rotor Technical Data
Rotor |
Capacity |
Max Speed |
Max RCF |
|
NO. 1 Swing-out Rotor |
4x100ml |
5000rpm |
4650 xg |
|
4x50ml |
||||
NO. 2 Swing-out Rotor |
32x15ml |
4000rpm |
2980 xg |
|
8x50ml |
||||
8x100ml |
||||
48×2-7ml Vacuum blood collection tube |
4000 rpm |
3100 xg |
||
64×2-7ml Vacuum blood collection tube |
|
|
||
NO. 3 Swing-out Rotor |
4x250ml(with a wind cover) |
5000rpm |
5200xg |
|
Adaptor |
8x50ml |
|||
4x100ml |
||||
36x10ml |
||||
20x15ml |
||||
NO. 4 Swing-out Microplate Rotor |
2x3x96 holes |
4000rpm |
1970xg |
|
NO.5 Swing-out Rotor |
Round hang cup |
4x500ml |
4000rpm |
3400xg |
Adaptor |
12x50ml |
|||
36x15ml |
||||
76×2-7ml Vacuum blood collection tube |
||||
Swing bucket rotor |
20x50ml |
|||
40x15ml |
||||
80x10ml Vacuum blood collection tube |
||||
112×2-7ml Vacuum blood collection tube |
||||
100×1.5ml |
||||
Hang cup |
148x5ml RIA tube |
|||
96×2-7ml Vacuum blood collection tube |
||||
Swing-out Microplate Rotor |
4x2x96 holes |
|||
NO. 6 Swing-out Rotor |
4x750ml |
4000rpm |
3500xg |
|
Adaptor |
12x100ml |
|||
20x50ml |
||||
48x15ml |
||||
96×2-7ml Vacuum blood collection tube |
||||
NO. 7 Swing-out Rotor |
6x250ml |
4000rpm |
3580xg |
|
Adaptor |
60×2-7ml Vacuum blood collection tube |
|||
30x15ml |
||||
No.8 Swing-out Rotor |
4x800ml |
4000rpm |
3580xg |
|
Adaptor |
56x15ml |
|||
140×2-7ml Vacuum blood collection tube |
||||
16x100ml |
LD-6M Floor standing low speed large capacity refrigerated centrifuge
Features & Advantages
• Variable frequency motor, microcomputer control.
• LCD & Digital display.
• It has many kinds of protection, such as overspeed, overtemperature, unbalance, and self-diagnosis protection
• 40 levels of acceleration and deceleration, and it can store 12 users programs.
• Imported compressor, double circuit control for refrigeration and heating and precise in temperature control.
• Electronic lock & controlled by independent motor
• Adopts Import famous variable frequency controller, control speed accurately and be durable.
• Programs of RCF can be set up directly.
• All- steel body ,three-layer steel for safety.
Technique Parameter
Max Speed |
6000 r/min |
Max RCF |
6880 Xg |
Max Capacity |
6x1000ml(4500rpm) |
Speed Accuracy |
±10r/min |
Temp Accuracy |
±1℃ |
Temp Range |
-20℃~40℃ |
Timer Range |
1min~99H59 min/inching |
Noise |
≤65dB(A) |
Power |
AC 220V 50HZ 30A |
Dimension |
850x730x930(LxWxH) mm |
Weight |
260 kg |
Rotor Technical Data
Rotor |
Capacity |
Max Speed |
Max RCF |
NO.1 Fixed-angle Rotor |
6x500ml |
6000r/min |
6880Xg |
NO. 2 Swing-out Rotor |
6x1000ml |
4500r/min |
5880Xg |
NO.3 Swing-out Rotor |
210×2-7ml vacuum blood collection tube |
4200 r/min |
5180Xg |
LD-8M Floor standing high speed large capacity refrigerated centrifuge
Features & Advantages
• Easy operation with touch-sensitive LCD
• The parameter setting can be directly digitally inputted and accurately put in single digit.
• Intelligent status prompt can display instrument status in real time.
• Large storage space can store up to 1000 program groups,1000 usage records and 1000 fault records.
• With time display function, including year, month, day, hour, minute and second, which is convenient to trace the usage record.
• Two timing methods are available:Hour/Minutes or Minutes/Seconds.
• Two timing models are optional: count or countdown
• 40 levels of acceleration and deceleration and can set the model of free stop.
• The speed, RCF and temp.curves are displayed on the same screen, and the change relationship can be seen clearly.
• Password lock function:Users can set a password to lock machine and parameter to prevent others from changing.
• Speed and RCF can be automatically converted and displayed in one screen.
• 22 kinds of protection functions such as over-speed, over-pressure, over-heat and so on. Prompt function with voice and text simultaneously
• With electronic manual which can never lost and easy to use.
• Variable frequency drive motor which in great torque, free maintenance
• The flexible axle driven system which drive the rotor directly, smooth in operation
• 3 levels vibration system which results in the best centrifugal effect.
• Imported compressor, CFC-free refrigerants, double circuit control for refrigeration and heating, precise in temperature control.
• Max capacity for blood bag is 18 x 400ml, and for centrifuge bottle, max capacity is 6 x 2400ml
Technique Parameter
Max Speed |
8000r/min |
Max RCF |
11880 xg |
Max Capacity |
6×2400ml or 18×400ml blood bag |
Speed Accuracy |
±20r/min |
Temp Accuracy |
±1℃ |
Temp Range |
-20℃~40℃ |
Timer Range |
1min~9H59 min/inching |
Noise |
≤60dB(A) |
Power Supply |
AC 380V 50HZ 35A |
Dimension |
960×880×950 (LxWxH) mm |
Weight |
560 Kg |
Power |
7.5 KW |
Rotor Technical Data
Rotor |
Capacity |
Max Speed |
Max RCF |
NO.1 Swing-out Rotor |
6×2400ml |
4200r/min |
6180xg |
NO. 2 Fixed-angle Rotor |
6×1000ml |
7000r/min |
11630xg |
NO. 3 Fixed-angle Rotor |
6×500ml |
8000r/min |
11880xg |
Product detail pictures:
Related Product Guide:
No matter new customer or old customer, We believe in long term and trusted relationship for Factory making Anti-Il-6 Antibody - Floor standing low speed large capacity refrigerated centrifuge – LuoRon , The product will supply to all over the world, such as: Bangkok, Adelaide, Bangladesh, If you are for any reason unsure which product to select, do not hesitate to contact us and we are going to be delighted to advise and assist you. This way we are going to be providing you with all the knowledge needed to make the best choice. Our company strictly follows "Survive by good quality, Develop by keeping good credit. " operation policy. Welcome all the clients old and new to visit our company and talk about the business. We have been looking for more and more customers to create the glorious future.
By Beryl from Algeria - 2018.06.18 19:26
We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
By Lena from Macedonia - 2018.02.21 12:14