Factory directly Anti-T4 Antibody - Water-Jacketed CO₂ Incubator – LuoRon Detail:
HEPA filter
HF160W applies long term effectiveness of the HEPA filter to protect your cultures. The filter is very efficient to entrap particulates larger than 0.3μm at 99.97%. The HEPA filter system runs continuously and within every 60 seconds, the volume of entire chamber is disinfected. With help of HEPA filter, the air quality achieves Class 100 clean room levels within 5 minutes following a door opening.
Airflow system
Optimized air flow system ensures the temperature and CO2 concentration to be stable and uniform within the chamber.
AUTO-ZERO/AUTO-START
HF160W combines precise CO2 control with a choice of TC or IR sensors. The microprocessor will automatically “Zero” the incubator(IR type) using room air as a reference every 24 hours. Auto-start function for TC type ensures the sensor’s beseline automatically reset without manual adjustment. These features will maintain an accurate CO2 control without worrying about CO2 drift.
Automatic control door heater
The outer door incorporates a door heater which is interlocked with the surrounding temperature monitoring system. This prevents temperature differences between the chamber and the inner door, thereby preventing condensation.
Humidity display and alarming system
HF160W is able to create a high humidity environment and the relative humidity (RH) is displayed on the panel, readable in 0.1% increments, including low RH programmable alarm(alerts you of need to add water)
Space Utility
HF160W is able to create a high humidity environment and the relative humidity (RH) is displayed on the panel, readable in 0.1% increments, including low RH programmable alarm(alerts you of need to add water)
Automatic gas cylinder switchover system
This system automatically switches from the primary to secondary gas cylinder when CO2 gas level does not change while an injection valve is open.
A. power switch
B. camber gas sample port
C. fill port
D. CO2 sensor
E. temperature sensor
F. humidity sensor
G. piling leg
H. mirror finish shelves
I. water jacket
J. glass fibre insulator
K. high efficiency HEPA
L. magnetic gasket
M. outer door heater
N. water pan
O. water jacket drain
P. coved corner
HF160W Specifications
HF160W Specifications |
|||
Construction |
655×656×1030(mm) 25.8×25.8×40.5(inch) |
Humidity |
Humidity pan |
Exterior dimensions (W×D×H) |
544×504×681(mm) 21.4×19.8×26.8(inch) |
Humidifying system |
Standard |
Interior dimensions (W×D×H) |
185L/6.5cu.ft. |
Humidifying sensor |
≥95% |
Interior Volume |
43.5L/1.54cu.ft. |
Relative humidity |
In 0.1% increments |
Water jacket volume |
110kg/242lbs |
Display |
3L |
Net Weight |
Type 304, mirror finish stainless steel |
Water reservior volume |
“466×440(mm)18.3×17.3(inch) |
Interior |
cold-rolled steel, power coated |
Shelves |
Type 304, mirror finish, stainless steel |
Exterior |
one inner door standard |
Shelf dimensions (W×D) |
3,11 |
Inner door |
Water Jacket |
Shelf construction |
Standard |
Temperature |
Microprocessor |
Standard, Maximum |
0.3μm,Efficiency:99.998% (for CO2) |
Heating method |
PT1000 |
Fittings |
Standard |
Temp. control system |
5℃ above ambient temperature to 55℃ |
Access port |
HEPA filter system |
Temp. sensor |
±0.2℃ |
Air filter |
430W |
Temp. range |
±0.1℃ |
Remote alarm contacts |
220V/50Hz (standard), |
Temp. uniformity |
0.1 MPa |
De-contamination |
110V/60Hz (Optional) |
Temp. stability |
Microprocessor |
Rated power |
Power interruption * High/low temperature * |
CO2 |
Thermal conductivity/Infrared |
Power supply |
Deviation of CO2 * RH * Door ajar * |
Inlet pressure |
0 to 20% |
Alarm system |
Independent overheat protection |
CO2 control system |
±0.1% |
Data output |
RS232 |
CO2 sensor |
655×656×1030(mm) 25.8×25.8×40.5(inch) |
Humidity |
Humidity pan |
CO2 range |
544×504×681(mm) 21.4×19.8×26.8(inch) |
Humidifying system |
Standard |
CO2 stability |
185L/6.5cu.ft. |
Humidifying sensor |
≥95% |
Product detail pictures:
Related Product Guide:
We've got a highly efficient group to deal with inquiries from shoppers. Our purpose is "100% client fulfillment by our product high-quality, price tag & our staff service" and enjoy a superb reputation amongst clientele. With quite a few factories, we will provide a wide variety of Factory directly Anti-T4 Antibody - Water-Jacketed CO₂ Incubator – LuoRon , The product will supply to all over the world, such as: Senegal, Argentina, Ukraine, We taking advantage of experience workmanship, scientific administration and advanced equipment, ensure the product quality of production, we not only win the customers' faith, but also build up our brand. Today, our team is committed to innovation, and enlightenment and fusion with constant practice and outstanding wisdom and philosophy, we cater to the market demand for high-end goods, to do experienced products and solutions.