Our advancement depends over the superior machines, exceptional talents and continually strengthened technology forces for Volumetric Pipette, Cell Culture Flask, 10ul Pipette Tips Manufacturer, To benefit from our strong OEM/ODM capabilities and considerate services, please contact us today. We will sincerely create and share success with all clients.
Factory directly Anti-T4 Antibody - Water-Jacketed CO₂ Incubator – LuoRon Detail:

HEPA filter

HF160W applies long term effectiveness of the HEPA filter to protect your cultures. The filter is very efficient to entrap particulates larger than 0.3μm at 99.97%. The HEPA filter system runs continuously and within every 60 seconds, the volume of entire chamber is disinfected. With help of HEPA filter, the air quality achieves Class 100 clean room levels within 5 minutes following a door opening.
2
2

Airflow system

Optimized air flow system ensures the temperature and CO2 concentration to be stable and uniform within the chamber.

AUTO-ZERO/AUTO-START

HF160W combines precise CO2 control with a choice of TC or IR sensors. The microprocessor will automatically “Zero” the incubator(IR type) using room air as a reference every 24 hours. Auto-start function for TC type ensures the sensor’s beseline automatically reset without manual adjustment. These features will maintain an accurate CO2 control without worrying about CO2 drift.

Automatic control door heater

The outer door incorporates a door heater which is interlocked with the surrounding temperature monitoring system. This prevents temperature differences between the chamber and the inner door, thereby preventing condensation.

Humidity display and alarming system

HF160W is able to create a high humidity environment and the relative humidity (RH) is displayed on the panel, readable in 0.1% increments, including low RH programmable alarm(alerts you of need to add water)
2
2

Space Utility

HF160W is able to create a high humidity environment and the relative humidity (RH) is displayed on the panel, readable in 0.1% increments, including low RH programmable alarm(alerts you of need to add water)

Automatic gas cylinder switchover system

This system automatically switches from the primary to secondary gas cylinder when CO2 gas level does not change while an injection valve is open.
2
2

A. power switch

B. camber gas sample port

C. fill port

D. CO2 sensor

E. temperature sensor

F. humidity sensor

G. piling leg

H. mirror finish shelves

I. water jacket

J. glass fibre insulator

K. high efficiency HEPA

L. magnetic gasket

M. outer door heater

N. water pan

O. water jacket drain

P. coved corner

HF160W Specifications

HF160W Specifications

Construction

655×656×1030(mm) 25.8×25.8×40.5(inch)

Humidity

Humidity pan

Exterior dimensions (W×D×H)

544×504×681(mm) 21.4×19.8×26.8(inch)

Humidifying system

Standard

Interior dimensions (W×D×H)

185L/6.5cu.ft.

Humidifying sensor

≥95%

Interior Volume

43.5L/1.54cu.ft.

Relative humidity

In 0.1% increments

Water jacket volume

110kg/242lbs

Display

3L

Net Weight

Type 304, mirror finish stainless steel

Water reservior volume

“466×440(mm)18.3×17.3(inch)

Interior

cold-rolled steel, power coated

Shelves

Type 304, mirror finish, stainless steel

Exterior

one inner door standard

Shelf dimensions (W×D)

3,11

Inner door

Water Jacket

Shelf construction

Standard

Temperature

Microprocessor

Standard, Maximum

0.3μm,Efficiency:99.998% (for CO2)

Heating method

PT1000

Fittings

Standard

Temp. control system

5℃ above ambient temperature to 55℃

Access port

HEPA filter system

Temp. sensor

±0.2℃

Air filter

430W

Temp. range

±0.1℃

Remote alarm contacts

220V/50Hz (standard),

Temp. uniformity

0.1 MPa

De-contamination

110V/60Hz (Optional)

Temp. stability

Microprocessor

Rated power

Power interruption * High/low temperature *

CO2

Thermal conductivity/Infrared

Power supply

Deviation of CO2 * RH * Door ajar *

Inlet pressure

0 to 20%

Alarm system

Independent overheat protection

CO2 control system

±0.1%

Data output

RS232

CO2 sensor

655×656×1030(mm) 25.8×25.8×40.5(inch)

Humidity

Humidity pan

CO2 range

544×504×681(mm) 21.4×19.8×26.8(inch)

Humidifying system

Standard

CO2 stability

185L/6.5cu.ft.

Humidifying sensor

≥95%


Product detail pictures:

Factory directly Anti-T4 Antibody - Water-Jacketed CO₂ Incubator – LuoRon detail pictures

Factory directly Anti-T4 Antibody - Water-Jacketed CO₂ Incubator – LuoRon detail pictures

Factory directly Anti-T4 Antibody - Water-Jacketed CO₂ Incubator – LuoRon detail pictures

Factory directly Anti-T4 Antibody - Water-Jacketed CO₂ Incubator – LuoRon detail pictures


Related Product Guide:

The corporate keeps towards the operation concept "scientific administration, superior quality and performance primacy, client supreme for Factory directly Anti-T4 Antibody - Water-Jacketed CO₂ Incubator – LuoRon , The product will supply to all over the world, such as: Bandung, Greek, Grenada, Our company warmly invites domestic and overseas customers to come and negotiate business with us. Let us join hands to create a brilliant tomorrow! We are looking forward to cooperating with you sincerely to achieve a win-win situation. We promise to try our best to provide you with high quality and efficient services.
  • We are long-term partners, there is no disappointment every time, we hope to maintain this friendship later!
    5 Stars By Jerry from Amsterdam - 2018.09.16 11:31
    Problems can be quickly and effectively resolved, it is worth to be trust and working together.
    5 Stars By Jerry from Slovakia - 2018.04.25 16:46
    Write your message here and send it to us