• lab-217043_1280

Blood collection tube automatic decapping centrifuge

Blood collection tube automatic decapping centrifuge feature

• Variable frequency drive motor,maintenance-free ,control speed accurately

• Automatically remove the vacuum blood tube cap during centrifuging, improving work efficiency

• Low,medium, high efficient filter system can filter noxious gas after centrifuging and decapping promptly, effectively avoid the cross infection of samples, and reduce the risk of infection by bacteria of operators.

• LCD & Digital display, touching key.

• Stainless steel chamber, all-steel body

• electronic locks

• 40 levels of acceleration and deceleration,and it can store 12 users programs.


Product Detail

Product Tags

DD-5G Bio-safety filtering automatic decapping centrifuge

LD-5G-1

Features & Advantages

• RCF can be set up directly

• Three-layer steel body for safety

• Adopts Import famous variable frequency controller, control speed accurately and be durable

• Centrifugation and cap-off can be completed at once to avoid remixing of samples after separation

• Suitable for vacuum Vacuum blood collection tubes with various capacity

• UV sterilization device is optional

Technique Parameter

Max speed

5000 r/min

Max RCF

5200 xg

Max Capacity

4x250ml

Speed Accuracy

±10r/min

Timer Range

1min~99H59min/inching

Noise

≤60dB(A)

Power

AC 220V 50HZ 15A

Motor

Variable frequency drive motor

Dimension

650x550x840(LxWxH) mm

Weight

135 kg

Rotor Technical Data

Rotor

Capacity

Max Speed

Max RCF

NO. 1 Swing-out Rotor

4x250 ml

5000rpm

5200xg

NO. 2 Swing-out Rotor(with automatic cap off function)

80x7ml

4000rpm

3400xg

NO. 3 Swing-out Rotor

(with automatic cap off function)

120x7ml

4000rpm

3580xg

NO. 4 Swing-out Rotor

(with automatic cap off function)

140x7ml

4000rpm

3580xg

LD-5G Blood collection tube automatic decapping centrifuge

LD-5G-1

Features & Advantages

• Variable frequency drive motor,maintenance-free, control speed accurately

• Automatically remove the vacuum blood tube cap during centrifuging, improving work efficiency

• Instead of handmade cap-off, prevent reagent contact with the human body, reduce the risk of infection

• LCD & Digital display, touching key.

• Stainless steel chamber, all-steel body

• electronic locks

• Imported compressor, CFC-free refrigerants

• 40 levels of acceleration and deceleration,and it can store 12 users programs.

• RCF can be set up directly

• Three-layer steel body for safety

• Adopts Import famous variable frequency controller, control speed accurately and be durable

• Centrifugation and cap-off can be completed at once to avoid remixing of samples after separation

• Suitable for vacuum Vacuum blood collection tubes with various capacity

Technique Parameter

Max speed

5000 r/min

Max RCF 

5200 xg

Max Capacity 

4x250ml

Speed Accuracy 

±10r/min

Temperature Range 

-20℃~40℃

Temperature Accuracy 

±1℃

Timer Range 

1min~99H59min/inching

Noise

≤60dB(A)

Power Supply 

AC 220V 50HZ 15A

Motor

Variable frequency drive motor

Dimension

650x550x840(LxWxH) mm

Weight

165 kg

Power

1.8KW

Rotor Technical Data

Rotor

Capacity

Max Speed

Max RCF

NO. 1 Swing-out Rotor

4x250 ml

5000rpm

5200xg

NO. 2 Swing-out

(with automatic cap off function)

80x7ml

4000rpm

3400xg

NO. 3 Swing-out Rotor

(with automatic cap off function)

120x7ml

4000rpm

3580xg

NO. 4 Swing-out Rotor

(with automatic cap off function)

140x7ml

4000rpm

3580xg

TD-5G Benchtop Blood Tube Automatic Decapping Centrifuge

TD-5G-3

Features & Advantages

• Variable frequency drive motor,maintenance-free,control speed accurately.

• Automatically remove the vacuum blood tube cap during centrifuging, improving work efficiency

• Instead of handmade cap-off, prevent reagent contact with the human body, reduce the risk of infection.

• LCD & Digital display, touching key.

• Stainless steel chamber, all-steel body

• electronic locks.

• RCF can be set up directly.

• Centrifugation and cap-off can be completed at once to avoid remixing of samples after separation

• Suitable for vacuum Vacuum blood collection tubes with various capacity.

Technique Parameter

Max speed

5000 r/min

Max RCF

5200 xg

Max Capacity

4x250ml

Speed Accuracy

±10r/min

Timer Range

1min~9999 min59s/inching/continuous

Noise

≤60dB(A)

Power

AC 220V 50HZ 10A

Motor

550x450x365(LxWxH) mm

Dimension

45 kg

Rotor Technical Data

Rotor

Capacity

Max Speed

Max RCF

NO. 1 Swing-out Rotor

4x250 ml

5000rpm

5200xg

NO. 2 Swing-out Rotor

32x7 ml

4000rpm

3100xg

NO. 3 Swing-out Rotor

(with automatic cap off function)

56x7ml

4000rpm

3400xg

NO. 4 Swing-out Rotor

(with automatic cap off function)

80x7ml


  • Previous:
  • Next:

  • Write your message here and send it to us